Abstract:
In this study, the critical fl ux of the submerged membrane system was experimentally evaluated when it was used for seawater with and without pre-treatment. In this study, different processes such as fl occulation with ferric chloride (FeCl3) and different doses of PAC adsorption were used as a pre-treatment. The pretreatment of fl occulant of 2 mg/L of FeCl3 and adsorption with the dose of 1 g/L PAC showed an improvement in the critical fl ux from 5 L/m2.h to 6.7 L/m2.h and 13.3 L/m2.h respectively. The performance of these pretreatments was also determined in terms of modifi ed fouling index using ultrafi lter membrane (UF-MFI). UF-MFI and SDI indicated that PAC adsorption was a better pretreatment than fl occulation for the seawater used in this study. Molecular weight distribution (MWD) of seawater organic matter was also examined after different pretreatments. MWD of the raw seawater was mainly in the range from 1510 to 130 Da. It is observed that FeCl3 fl occulation and PAC adsorption as pretreatments partially removed the organic matter of 1510 Da and 130Da respectively