Abstract:
The comparison of two or more samples of liquid gasoline (petrol) to establish a common origin is a difficult problem in the
forensic investigation of arsons and suspicious fires. A total of 35 randomly collected samples of unevaporated gasoline, covering
three different grades (regular unleaded, premium unleaded and lead replacement), were examined. The high-boiling fraction of
the gasoline was targeted with a view to apply the techniques described herein to evaporated gasoline samples in the future.
A novel micro solid phase extraction (SPE) technique using activated alumina was developed to isolate the polar compounds
and the polycyclic aromatic hydrocarbons (PAHs) from a 200 JlI sample of gasoline. Samples were analysed using full-scan gas
chromatography-mass spectrometry (GC-MS) and potential target compounds identified. Samples were then re-analysed
directly, without prior treatment, using GC-MS in selected ion monitoring (SIM) mode for target compounds that exhibited
variation between gasoline samples. Principal component analysis (PCA) was applied to the chromatographic data. The first two
principal components (PCs) accounted for 91.5% of the variation in the data. Linear discriminant analysis (LDA) performed on
the PCA results showed that the 35 samples tested could be classified into 32 different groups.