Abstract:
An incremental integral isoconversional method for the determination of activation energy as a function
of the extent of conversion is presented. The method is based on the treatment of experimental
data without their transformation so that the resulting values of activation parameters should not be
biased. The method was tested for recovering the activation energies from simulated data and employed
for the treatment of experimental data of the NiS recrystallisation.