Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques

UTSePress Research/Manakin Repository

Search UTSePress Research


Advanced Search

Browse

My Account

Show simple item record

dc.contributor.author Dwyer, Donovan en_US
dc.contributor.author Fry, Margaret en_US
dc.contributor.author Sommerville, Annabel en_US
dc.contributor.author Holdgate, Anna en_US
dc.date.accessioned 2009-12-21T02:33:05Z
dc.date.available 2009-12-21T02:33:05Z
dc.date.issued 2006 en_US
dc.identifier 2007001247 en_US
dc.identifier.citation Dwyer Donovan et al. 2006, 'Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques', Blackwell Publishing, vol. 18, pp. 484-487. en_US
dc.identifier.issn 1742-6731 en_US
dc.identifier.other C1UNSUBMIT en_US
dc.identifier.uri http://hdl.handle.net/10453/4384
dc.description.abstract Objective: Blood aspiration through i.v. cannulae is a common ED sampling method. It is, however, associated with increased haemolysis rates when compared with direct venipuncture. Our ED utilizes two common methods of sampling through cannulae. The aim of the present study was to examine the haemolysis rates for these two techniques. Methods: A randomized, single blinded prospective study was performed. From a convenience sample patients were randomized to either `Method one? (blood taken directly from cannula hub) or `Method two? (blood taken using an Interlink device through cannula cap). For each group patient demographics, clinical information and haemolysis were analysed. ?<sup>2</sup>-analysis and a multivariate logistic regression model were applied to determine significant relationships. Results: A total of 1390 patients were enrolled, 694 had blood collected by `Method one? and 696 by `Method two?, with haemolysis rates of 6.5% and 7.2%, respectively. Univariate analysis showed ease of aspiration to be the only variable to have a strong association with haemolysis ( P < 0.0001). After allowing for ease of aspiration the technique used did not significantly affect haemolysis rate ( P = 0.7). Conclusions: The rate of haemolysis is unrelated to the technique of blood aspiration. However, haemolysis rates increase significantly with perceived difficulty of blood draw. en_US
dc.publisher Blackwell Publishing en_US
dc.title Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques en_US
dc.parent Emergency Medicine Australasia en_US
dc.journal.volume 18 en_US
dc.journal.number en_US
dc.publocation Carlton South, Australia en_US
dc.identifier.startpage 484 en_US
dc.identifier.endpage 487 en_US
dc.cauo.name FOH.Faculty of Health en_US
dc.conference Verified OK en_US
dc.for 110300 en_US
dc.personcode 0000036643 en_US
dc.personcode 103222 en_US
dc.personcode 0000036644 en_US
dc.personcode 0000036640 en_US
dc.percentage 100 en_US
dc.classification.name Clinical Sciences en_US
dc.classification.type FOR-08 en_US
dc.description.keywords aspiration; cannula; haemolysis; technique; venipuncture en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record