Time-varying stroke volume using sonomicrometry with direct cardiac compression (DOC)

UTSePress Research/Manakin Repository

Search UTSePress Research


Advanced Search

Browse

My Account

Show simple item record

dc.contributor.author Hunyor, S. N en_US
dc.contributor.author Plekhanov, S. en_US
dc.contributor.author Huang, Y. en_US
dc.contributor.author Martinez-Coll, A. en_US
dc.contributor.author Nguyen, H. T en_US
dc.contributor.editor Chorbel FH en_US
dc.date.accessioned 2009-11-09T05:37:40Z
dc.date.available 2009-11-09T05:37:40Z
dc.date.issued 2002 en_US
dc.identifier 2004003392 en_US
dc.identifier.citation Martinez-Coll, A. et al. 2002 'Time-varying stroke volume using sonomicrometry with direct cardiac compression (DOC)', Second Joint EMBS-BMES Conference 2002 - Engineering in Medicine and Biology Society Annual Fall Meeting of the Biomedical Engineering Society, The Institute of Electrical and Electronic Engineers Inc (IEEE), Houston, Texas, USA, pp. 1567-1568. en_US
dc.identifier.issn 0-7803-7612-9 en_US
dc.identifier.other E1 en_US
dc.identifier.uri http://hdl.handle.net/10453/3001
dc.description.abstract Implantable direct cardiac compression (DCC) systems such as our Heart Patch Pump can assist the failing heart without the risk of blood contact. To provide realtime, accurate support of pumping function, these devices need to assess hemodynamic variables such as cardiac output. For the Heart Patch Pump, we have based our control algorithm on time-varying stroke volume (SV(t)) estimates using sonomicrometer crystals placed in the heart. Multilinear regression was performed on 28 dimensions, during six different cardiac states. Then, six principal dimensions were identified as those with the greatest change during contraction. A strong correlation was maintained in all cardiac states when only the principal dimensions were used. en_US
dc.publisher The Institute of Electrical and Electronic Engineers Inc (IEEE) en_US
dc.relation.isbasedon http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1106541&isnumber=24325 en_US
dc.subject Direct cardiac compression. en
dc.subject Heart Patch Pump. en
dc.title Time-varying stroke volume using sonomicrometry with direct cardiac compression (DOC) en_US
dc.parent EMBS 2002 BMES en_US
dc.journal.volume en_US
dc.journal.number en_US
dc.publocation New Jersey, USA en_US
dc.identifier.startpage 1567 en_US
dc.identifier.endpage 1568 en_US
dc.cauo.name Engineering en_US
dc.conference Second Joint EMBS-BMES Conference 2002 - Engineering in Medicine and Biology Society Annual Fall Meeting of the Biomedical Engineering Society en_US
dc.conference.location Houston, Texas, USA en_US