Performance of dry electrode with bristle in recording EEG rhythms across brain state changes

UTSePress Research/Manakin Repository

Search UTSePress Research


Advanced Search

Browse

My Account

Show simple item record

dc.contributor.author Kitoko, Vangu en_US
dc.contributor.author Nguyen, Jordan en_US
dc.contributor.author Tran, Yvonne en_US
dc.contributor.author Nguyen, Hung en_US
dc.contributor.author Nguyen, Nghia en_US
dc.contributor.editor Technical Committee en_US
dc.date.accessioned 2012-10-12T03:36:29Z
dc.date.available 2012-10-12T03:36:29Z
dc.date.issued 2011 en_US
dc.identifier 2011001515 en_US
dc.identifier.citation Kitoko Vangu et al. 2011, 'Performance of dry electrode with bristle in recording EEG rhythms across brain state changes', , IEEE, Boston, USA, , pp. 59-62. en_US
dc.identifier.issn 978-1-4244-4121-1 en_US
dc.identifier.other E1 en_US
dc.identifier.uri http://hdl.handle.net/10453/19248
dc.description.abstract In this paper we evaluate the physiological performance of a silver-silver chloride dry electrode with bristle (B-Electrode) in recording EEG data. For this purpose, we compare the performance of the bristle electrode in recording EEG data with the standard wet gold-plated cup electrode (G-Electrode) using two different brain state change tasks including resting condition with eyes-closed and performing mathematical task with eyes-open. Using a 2 channel recording device, eyes-closed command data were collected from each of 6 participants for a period of 20sec and the same procedure was applied for the mathematical calculation task. These data were used for statistical and classification analyse. Although, B-electrode has shown a slightly higher performance compared with G-electrode in both tasks, but analyse did not reveal any significant differences between both electrodes in all six subjects tested. en_US
dc.language English en_US
dc.publisher IEEE en_US
dc.relation.hasversion Accepted manuscript version en_US
dc.relation.isbasedon http://dx.doi.org/10.1109/IEMBS.2011.6089896 en_US
dc.title Performance of dry electrode with bristle in recording EEG rhythms across brain state changes en_US
dc.parent Engineering in Medicine and Biology Society,EMBC, 2011 Annual International Conference of the IEEE en_US
dc.journal.volume en_US
dc.journal.number en_US
dc.publocation Boston, USA en_US
dc.identifier.startpage 59 en_US
dc.identifier.endpage 62 en_US
dc.cauo.name FEIT.School of Elec, Mech and Mechatronic Systems en_US
dc.conference Verified OK en_US
dc.for 090300 en_US
dc.personcode 10948420 en_US
dc.personcode 101809 en_US
dc.personcode 102950 en_US
dc.personcode 960936 en_US
dc.personcode 840115 en_US
dc.percentage 100 en_US
dc.classification.name Biomedical Engineering en_US
dc.classification.type FOR-08 en_US
dc.edition en_US
dc.custom Annual International Conference of the IEEE Engineering in Medicine and Biology Society en_US
dc.date.activity 20110830 en_US
dc.location.activity Boston, USA en_US
dc.description.keywords en_US
dc.staffid 840115 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record