| dc.contributor.author | Du Hui | en_US |
| dc.contributor.author | Davidson Patricia | en_US |
| dc.contributor.author | Everett Bronwyn | en_US |
| dc.contributor.author | Salamonson Yenna | en_US |
| dc.contributor.author | Zecchin Robert | en_US |
| dc.contributor.author | Rolley John | en_US |
| dc.contributor.author | Newton Phillip | en_US |
| dc.contributor.author | Macdonald Peter | en_US |
| dc.contributor.editor | en_US | |
| dc.date.accessioned | 2012-02-10T06:09:40Z | |
| dc.date.available | 2012-02-10T06:09:40Z | |
| dc.date.issued | 2011 | en_US |
| dc.identifier | 2010005547 | en_US |
| dc.identifier.citation | Du Hui et al. 2011, 'Correlation between a self-administered walk test and a standard six minute walk test in adults', Blackwell Publishing, vol. 13, no. 2, pp. 114-117. | en_US |
| dc.identifier.issn | 1441-0745 | en_US |
| dc.identifier.other | C1 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10453/17095 | |
| dc.description.abstract | This study was undertaken to assess the correlation between a self-administered, adapted Six Minute Walk Test (the Home-Heart-Walk) and the standard Six MinuteWalk Test based on the American Thoracic Society guideline.A correlational study was conducted at a university campus in Sydney,Australia. Thirteen healthy volunteers underwent the Home-Heart-Walk and the standard Six MinuteWalk Test on a single occasion.The distance that participants walked during the two tests was assessed using Pearson¿s correlation.The correlation between the Home-Heart-Walk and the Six Minute Walk Test distance was 0.81. The Home-Heart-Walk distance was highly correlated to the standard Six Minute Walk Test distance in this study. This relationship provides confidence for further research in populations to facilitate monitoring and evaluation. | en_US |
| dc.language | en_US | |
| dc.publisher | Blackwell Publishing | en_US |
| dc.relation.isbasedon | http://dx.doi.org/10.1111/j.1442-2018.2011.00605.x | en_US |
| dc.title | Correlation between a self-administered walk test and a standard six minute walk test in adults | en_US |
| dc.parent | Nursing and Health Sciences | en_US |
| dc.journal.volume | 13 | en_US |
| dc.journal.number | 2 | en_US |
| dc.publocation | Australia | en_US |
| dc.identifier.startpage | 114 | en_US |
| dc.identifier.endpage | 117 | en_US |
| dc.cauo.name | NMH.Faculty of Nursing, Midwifery and Health | en_US |
| dc.conference | Verified OK | en_US |
| dc.for | 111000 | en_US |
| dc.personcode | 0000070879;110950;107686;0000027623;0000066049;0000066051;111808;0000069618 | en_US |
| dc.percentage | 000100 | en_US |
| dc.classification.name | Nursing | en_US |
| dc.classification.type | FOR-08 | en_US |
| dc.edition | en_US | |
| dc.custom | en_US | |
| dc.date.activity | en_US | |
| dc.location.activity | en_US | |
| dc.description.keywords | functional capacity, self-monitoring, six minute walk test | en_US |
| dc.staffid | Curtin University of Technology;University of Western Sydney;Curtin University of Technology | en_US |