The Proposed Heating and Cooling System in the CH2 Building and Its Impact on Occupant Productivity

Lu Aye, Robert Fuller


Abstract

Melbourne's climatic conditions demand that its buildings require both heating and cooling systems. In a multi-storey office building , however, cooling requirements will dominate. How the internal space is cooled and ventilation air is delivered will significantly impact on occupant comfort. This paper discusses the heating and cooling systems proposed for the CH2building. The paper critiques the proposed systems against previous experience, both internationally and in Australia. While the heating system employs proven technologies, less established techniques are proposed for the cooling system. Air movement in the shower towers, for example, is to be naturally induced and this has not always been successful elsewhere. Phase change material for storage of "coolth" does not appear to have been demonstrated previously in a commercial building, so the effectiveness of the proposed system is uncertain. A conventional absorption chiller backs up the untried elements of the cooling system, so that ultimately occupant comfort should not be compromised .

Full Text

PDF

References

AEC (2003a), Passive Design Report, Advanced Environmental Concepts Pty Ltd., North Sydney, NSW.

AEC (2003b), Technical Design and Overview + Building Services Philosophy, Advanced Environmental Concepts Pty Ltd., North Sydney, NSW.

AEC (2003c), PCM Operational Report. Advanced Environmental Concepts Pty Ltd., North Sydney, NSW.

AEC (2003d), Productivity Benefits at CH2, Advanced Environmental Concepts Pty Ltd ., North Sydney, NSW.

Agas, G., Matsaggos, T., Santamouris, M. and Agryriou, A (1991), 'On the use of atmospheric heat sinks for heat dissipation', Energy and Buildings, vo1.17, pp.321-329. http://dx.doi.org/10.1016/0378-7788(91)90014-T

Alamdari, F, Butler, D.J.G., Grigg, PF and Shaw, M.R. (1998), 'Chilled ceilings and displacement ventilation', Renewable Energy, vo1.15, pp.300-305. http://dx.doi.org/10.1016/S0960-1481(98)00177-3

Alanne, K. and Saari, A (2004), 'Sustainable small-scale CHP technologies for buildings: the basis for multi-perspective decision making', Renewable and Sustainable Energy Reviews, vol.8, pp.401-431. http://dx.doi.org/10.1016/j.rser.2003.12.005

ASHRAE (1992), Thermal Environmental Conditions for Human Occupancy, ANSIIASHRAE Standard 55-1992, American Society of Heating, Refriger~tion and Airconditioning Engineers, Atlanta.

ASHRAE (2001), Fundamentals Handbook (SI) -Chapter 8 Thermal Comfort, American Society of Heating, Refrigeration and Airconditioning Engineers, Atlanta.

Bahadori, M.N. (1985), 'An improved design of wind towers for natural ventilation and passive cooling', Solar Energy, vo1.35, no.2, pp.119-129. http://dx.doi.org/10.1016/0038-092X(85)90002-7

Berglund, L.G. and Fobelets, A. (1987), 'A subjective human response to low level air currents and asymmetric radiation ', ASHRAE Transactions 93, no.1, pp.497-523.

Birtles, AB., Kolokotroni, M. and Perera, M.D.A.E.S. (1996), 'Night cooling and ventilation design for office-type buildings', Renewable Energy, vol.8, no.2, pp.259-263. http://dx.doi.org/10.1016/0960-1481(96)88858-6

Blondeau, P, Speradio, M. and Allard, F (1997), 'Night ventilation for building cooling in summer', Solar Energy, vol.61, no.5, pp.327--335. http://dx.doi.org/10.1016/S0038-092X(97)00076-5

CADDET (2002), 'Innovation ventilation system at Charles Sturt University', CADDET Reporter, Dept. of Industry, Tourism and Resources, vo1.35, June.CoM (2004), City of Melbourne website, http://www.melbourne.vic.gov.au/rsrc/PDFslCH2/pg2CoolingOffices.pdf.

de Dear, R. and Brager, G.S. (2001), 'The adaptive model of thermal comfort and energy conservation in the built environment', International Journal of Boimeteorology, vo1.45, pp.1 00-1 O8.

DLE and MGW (see: Davis Langdon & Everest and Mott Green & Wall) (2001), 'Chilled ceilings and beams', Building Services Journal, May, vols.22-23 & 26.

Duffie, JA and Beckman, W.A. (1991), Solar Engineering of Thermal Processes, Wiley-Interscience, New York.

Fang, L., Wyon, D.P., Clausen, G. and Fanger, P.O. (2004), 'Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance', Indoor Air, vo1.14, suppl.7, pp.74-81. http://dx.doi.org/10.1111/j.1600-0668.2004.00276.x

Fisk, W.J. and Rosenfeld, A.H. (1997), 'Estimates of improved productivity and health from better indoor environments', Indoor Air, vol. 7, pp.158-172. http://dx.doi.org/10.1111/j.1600-0668.1997.t01-1-00002.x

Givoni, B. (1994), Passive and Low Energy Cooling of Buildings, Van Nostrand Reinhold, New York, pp.263.

Hodder, S.G., Loveday, D.L., Parsons, K.C., and Taki, A.H. (1998), 'Thermal comfort in chilled ceiling and displacement ventilation environments: vertical radiant temperature asymmetry effects', Energy and Buildings, vo1.27, pp.167-173. http://dx.doi.org/10.1016/S0378-7788(97)00038-8

Kenton, G. (2004), 'Council House 2. Possibilities for Passive Design', presentation for the Sustainable Energy Authority of Victoria, 23 September 2004, Available on CD of design documents supplied by City of Melbourne.

Khudhair, A.M. and Farid, M.M. (2004), 'A review on energy conservation in building applications with thermal storage by latent heat using phase change materials', Energy Conservation and Management, vo1.45, no.2, pp.263-275. http://dx.doi.org/10.1016/S0196-8904(03)00131-6

Leaman, A. and Bordass, B. (1999), 'Productivity in buildings: the killer variables', Building Research and Information, vo1.27, no.1, ppA-19.

Lorsch, H.G. and Abdou, O.A. (1994), The impact of the building indoor environment on occupant productivity -Part 1: recent studies, measures and costs', ASHRAE Transactions, Paper No OR-94-8-2, pp.741-748.

Morrison, D.J. and Abdel-Khalik, S.1. (1978), 'Effects of phasechange energy storage on the performance of air-based and liquid-based solar heating systems', Solar Energy, vo1.20, no.1, pp.57-67.

Pearlmutter, D., Erell, E., Etzion, Y., Meir, lA and Di, H. (1996), 'Refining the use of evaporation in the experimental down-draft cool tower', Energy and Buildings, vo1.23, pp.191-197. http://dx.doi.org/10.1016/0378-7788(95)00944-2

PCA (see: Property Council of Australia) (1997), Victorian Energy Use Survey 1996, Property Council of Australia, Victorian Division, 31 pages.

Roy, G.G. and Miller, S.G. (1981), Data Handbook for Australian Solar Energy Designers, Research Report No. 7, School of Architecture, University of Western Australia.

SKM (2001), A Review of the Viability of Cogneration in Australia, report for Commonwealth Dept of Industry, Science and Resources and Australian EcoGeneration Association, Sinclair Knight Merz Pty Ltd., Ver. 2, Oct.

Tham, K.W. (2004), 'Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics', Indoor Air, vo1.14, suppl.7, pp.119-125. http://dx.doi.org/10.1111/j.1600-0668.2004.00280.x

Van der Maas, J. and Roulet, CA (1991), Nighttime Ventilation by Stack Effect, ASHRAE Trans., 97, part 1, pp.516-524.

Yeo, E. (2004), Charles Sturt University-Dubbo Stage 1. Interactive Learning Centre. Rectification of Cooling Systems Detailed Investigation Report, NSW Government Architect's Office, NSW Department of Commerce, Sydney.

Zalba, B., Marin, J.M., Cabeza, L.F. and Mehling, H. (2004), 'Free cooling of buildings with phase change materials', International Journal of Refrigeration, vo1.27, pp.839-849. http://dx.doi.org/10.1016/j.ijrefrig.2004.03.015

Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM