Cost Analyses of Measures to Improve Residential Energy Ratings to 6 Stars - Playford North Development, South Australia

Martin Belusko, Timothy O'Leary


Abstract

 

This paper reports the results of a study on the cost implications of achieving greater energy efficiency as measured by House Energy Rating(HER) ‘stars’ for new housing on a greenfield development in the northern suburbs of Adelaide. Twelve house designs typical of the housing options available from a number of builders engaged with this development were modeled using the 2nd generation Building Code of Australia (BCA) accredited energy rating assessment tool AccuRate. Where the model predicted a rating below the minimum rating (6 star) proposed under the recently agreed Commonwealth of Australia, National Energy Efficiency strategy, the designs were modified in order to improve the rating to 6 stars using a combination of specification changes and energy efficient technology options. These changes or options were then priced at prevailing building suppliers and subcontractors retail cost levels in order that an average ‘extra cost to 6 star’ and range of indicative costs to achieve 6 star housing compliance could be articulated. The results revealed that standard and currently available technologies, such a reflective foil barriers, increased insulation and low emissivity ‘e’ type glazing provide a means to achieving 6 star ratings at a modest additional cost, i.e. 1-2% of total construction and development costs.

Keywords

6 Star costs, Energy rating, Sustainability, Sustainable housing, Energy efficiency

Full Text

PDF

References

Australian Building Codes Board (ABCB) (2009) Supporting Commentary on the Proposals to Amend the Energy Efficiency Provisions in the Building Code of Australia Volume 2 for 2010, ABCB, Canberra, ACT

ASHRAE (2005) ASHRAE Handbook – Fundamentals, American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc., Atlanta, USA

Australian Window Association (AWA) (2009) Industry Capacity/Capability Study, Australian Window Association, Gordon, New South Wales

Athienitis A. and Santamouris. M. (2002) Thermal Analysis and Design of Passive Solar Buildings, James and James, London

Ambrose, M. Delsante, A. Johnson, D. and Tucker, S.N. (2004) Energy Efficiency Uptake Within the Project House Building Industry, CSIRO, Canberra, ACT

Burghardt, G. (2008) Study of the Thermal Performance of Class 2 Multiple Unit Dwellings using Accurate House Energy Rating Software, report for the Australian Building Codes Board, Nov. Canberra, ACT

Constructive Concepts (2009) Building Improvements To Raise House Energy Ratings From 5.0 Stars, Overview of Systematic AccuRate Modelling for the Australian Building Codes Board, Tony Isaacs Consulting, Australian Building Codes Board, Canberra, ACT

Council of Australian Governments (COAG), 2009 Communiqu–, Hobart April 2009 National Strategy on Energy Efficiency, Canberra ACT

Energy Efficient Strategies, (2002) Comparative Cost Benefit Study of Energy Efficiency Measures for Class 1 Buildings and High Rise Apartments, Report for the Sustainable Energy Authority of Victoria, Melbourne, Australia

Fricker, J (2002) 'The Diminishing Benefit of Extra Home Insulation', viewed at http://fricker.net.au accessed 09/06/09

Rawlinsons (2009) Australian Construction Handbook 2009, Rawlhouse Publishing Pty Ltd. Perth, Western Australia

Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM